Dongfeng off-road vehicle Electrical equipment common fault and exclude-EQ2082E6D, EQ2100E6D circuit often failure and exclude

First, the whole car is powerless

Cause Analysis:

1. The battery is electrically powerless, shorted or the battery is broken.

2, electromagnetic power supply is always open;

3, the current watch is falling off;

4, easy-flux linear or falling off;

5, the iron wire joint on the total switch of the electromagnetic power source is loose, and the contact is poor;

6. Cab indoor power supply has always turned down or the wire is falling off.

4Classic EQ2082 to change the car

Method of exclusion:

1. First, check whether the collision line joint on the total switch of the electromagnetic power source is loose, whether it is good, if the iron is not good,

Should be removed from the iron line and put the paint on the frame and then install the iron line;

2. Check whether the wire on the total switch of the electromagnetic power source has electricity. If no electricity, the battery is faulty or the battery is not electricity.

Exhaust, remove the battery cover, check if the battery is electricity, if there is electricity, pay attention to check the battery

Whether the pole line assembly is secure and reliable. If the negative electrode is loaded, the generator diode must be broken, and the generator is required to be corrected immediately;

3. Check if the easy-to-fusement of the cab electrical box is burnt or fall off. If there is, it will be corrected;

4. Check whether the line of the current table on the dashboard is off, if there is, it will be corrected;

5. Check if the power switch is damaged or if there is such a phenomenon, if there is this phenomenon, it will be corrected.

6. If the above-mentioned inspection methods have been excluded, the full vehicle powerless fault still exists, then check the power supply total switch solenoid valve.

Is there a malfunction, if there is, the electromagnetic power source switch should be replaced.

WeChat picture _20210908165759EQ2100 Dump truck

Second, the engine does not work (the reason for the analysis and circuitry):

1. The ignition lock is off;

2, the starter relay is bad;

3, the starter is bad. Method of exclusion:

1. Check if the ignition lock tab is falling off. If there is, it will be corrected;

2, screw the ignition lock to the startup, measure whether the starter line on the starter relay is fired with the test light, if not, then

The starter relay is bad;

3, if the starter relay is available, the magnetic switch on the starter is electrically, but it cannot start the starter, indicating the starter damage.

3E7AB9B355A3922508A1E3058CFBA86EQ2100 Truck

This article is reproduced from: Dongfeng Truck Corporation Heavy Car Factory - \"Military Dongfeng off-road vehicle Adjustment and Maintenance Manual\"

Hubei Off-Road Special Vehicle Co., Ltd.
Address: No. 6, Huimin Road, Maojian District, Shiyan City, Hubei Province, China
Tel: 86-719-8888190 Tel: 86-18986895008 / 86-18986890909 Email:fanya_trade@163.com
Copyright © 2021 Hubei Off-road Special Vehicle Co., Ltd. Record certificate number:Hubei ICP No. 20010516-3